3.5 Core Stranded Aluminium Power Cable, 3×50+25 mm2, XLPE Insulated, SWA Armored, 0.6/1kV, 500 m | Red Sea Cables

3.5 Core Stranded Aluminium Power Cable, 3×50+25 mm2, XLPE Insulated, SWA Armored, 0.6/1kV, 500 m | Red Sea Cables

(33 Product Views)

YouMats

Armoured stranded aluminium power cable (AL/XLPE/SWA/PVC), 3 core + neutral line, 3×50+25 mm2 size conductor, 0.6/1kV, Produced by Red Sea Cables (RESCAB) Company. Armored with layer of galvanized steel wires (SWA) to give it mechanical strength to protect it from external pressures that fall on the cable.

in stock
 Call Supplier
general.mada
general.master_card
general.visa
general.tamara

Product description

Armoured stranded aluminium power cable (AL/XLPE/SWA/PVC), 3 core + neutral line, Produced by Red Sea Cables (RESCAB) Company. Armored with layer of galvanized steel wires (SWA) to give it mechanical strength to protect it from external pressures that fall on the cable. Insulated with XLPE (cross-linked polyethylene), which offers an exceptional combination of properties that make it the ideal choice for a wide range of power and energy transmission applications due to its excellent electrical, thermal, and mechanical properties, where it is characterized by its ability to withstand high temperatures up to 90°C for extended periods without compromising performance. It also offers excellent resistance to moisture, corrosion, and chemicals, ensuring long-term safety of use. Additionally, sheathed with PVC (polyvinyl chloride) material, which provides extra protection for the cable against shocks, abrasion, corrosion, and prevents harmful UV rays from damaging the cable. This makes it suitable for both indoor and outdoor applications where there is a risk of mechanical damage. Available in different shapes, sizes and conductor ratings to meet diverse application requirements.

  • Conductor: Stranded Aluminium.
  • Insulation Material: XLPE (Cross-Linked Polyethylene)
  • Armoring: Galvanized Steel Wires (SWA)
  • Outer Sheath: PVC
  • Voltage: 0.6/1 kV
  • Number of Cores: 3.5 (3 Phases + Neutral Line)
  • Conductor Size: 3×50 mm² + 25 mm² (Neutral)
  • Number of Phase Wires: 7
  • Number of Neutral Wires: 7
  • Nominal Insulation Thickness (Phase): 1.0 mm
  • Nominal Insulation Thickness (Neutral): 0.9 mm
  • Nominal Steel Wire Diameter: 1.6 mm
  • Nominal Sheath Thickness: 2.0 mm
  • Approx. Overall Diameter: 38 mm
  • Max DC Resistance at 20°C (Phase): 0.641 ohm/km
  • Max DC Resistance at 20°C (Neutral): 0.641 ohm/km
  • Approx. Weight: 1830 kg/km
  • Standard Length: 500 meters
  • Phase Core Colors: Red, Yellow, Blue, Black
  • Standard: IEC 60502-1