3.5 Core Stranded Copper Electric Cable, 3x50+25mm2, XLPE Insulated, STA Armoured, 0.6/1kV, Length 500 meter | RESCAB

3.5 Core Stranded Copper Electric Cable, 3x50+25mm2, XLPE Insulated, STA Armoured, 0.6/1kV, Length 500 meter | RESCAB

(34 Product Views)

YouMats

Armored stranded copper power cable (CU/XLPE/STA/PVC), 3 core + neutral line, 3x50+25mm2 size conductor, low voltage 0.6/1kV, XLPE insulated for excellent heat resistance, PVC sheathed for protection against environmental impacts and abrasion. Produced by Red Sea Cables (RESCAB) Company.
 

in stock
 Call Supplier
general.mada
general.master_card
general.visa
general.tamara

Product description

Armored stranded copper power cable (CU/XLPE/STA/PVC), Produced by Red Sea Cables (RESCAB) Company according to the International Electrotechnical Commission standard (IEC 60502-1). Armored with a layer of galvanized steel tape (STA) to give it mechanical strength to protect it from external pressures that fall on the cable. Insulated with XLPE (cross-linked polyethylene), which offers an exceptional combination of properties that make it the ideal choice for a wide range of power and energy transmission applications due to its excellent electrical, thermal, and mechanical properties, where it is characterized by its ability to withstand high temperatures up to 90°C for extended periods without compromising performance. It also offers excellent resistance to moisture, corrosion, and chemicals, ensuring long-term safety of use. Additionally, it is sheathed with PVC (polyvinyl chloride) material, which provides extra protection for the cable against shocks, abrasion, and corrosion, and prevents harmful UV rays from damaging the cable. This makes it suitable for both indoor and outdoor applications where there is a risk of mechanical damage. Available in different shapes, sizes, and conductor ratings to meet diverse application requirements.

  • Conductor: Stranded Copper
  • Insulation Material: XLPE (Cross-Linked Polyethylene)
  • Armoring: Steel Tape (STA)
  • Outer Sheath: PVC
  • Voltage: 0.6/1kV
  • Number of Cores: 3.5 Core (3 Core + Neutral Line)
  • Conductor Size (Cross-Sectional Area): ( 3cx50 mm2 ) + 25mm2
  • Number of Phase Wires: 7
  • Number of Neutral Wires: 7
  • Nominal Insulation Thickness of Phase: 1.0 mm
  • Nominal Insulation Thickness of Neutral: 0.9 mm
  • Nominal Steel Tape Thickness: 0.2 mm
  • Nominal Sheath Thickness: 1.9 mm
  • Approx Overall Diameter: 30 mm
  • Max DC Conductor Resistance at 20°C (Ph): 0.387 ohm/km
  • Max DC Conductor Resistance at 20°C (Ne): 0.727 ohm/km
  • Weight: 2235 kg/km
  • Standard Length: 500 meters
  • Phase Core Colors: (Red, Yellow, Blue, Black)
  • Standard:  IEC 60502-1